Category Archives: plant damage

Nuclear plant safety standards may be thrown out

failed standards:   quake was 25% over max expected, despite 60% increase in 2006;  meltdown never expected;  radiation release is 100 times max expected;  10km  max evacuation zone was expected;  external power and backups would not both fail; Nuclear plant … Continue reading

Posted in doubtful assurances, incompetence, plant damage, radiation release | Leave a comment

Cooling spent fuel pool in Unit 4 hits a problem

TEPCO says it will be hard to repair a damaged pipe they had hoped could cool the still-overheated pool.  A new plan is needed. TEPCO forced to review reactor 4 cooling plan The operator of the Fukushima Daiichi nuclear power … Continue reading

Posted in plant damage | Leave a comment

Reactor #3 too radioactive for work – 100 mSv/hr overdoses workers

Radiation in No. 3 reactor too high for work The operator of the damaged Fukushima Daiichi nuclear plant says radiation levels in one of the reactor buildings remain too high for workers to do their jobs.
Tokyo Electric Power Company, or … Continue reading

Posted in plant damage, roadmap to repair, worker safety | Leave a comment

‘Melt-through’ at Fukushima? / Govt report to IAEA suggests situation worse than meltdown

excerpt:   fuel in three reactors has possibly melted through pressure vessels and accumulated at the bottom of outer containment vessels. See earlier announcements of 25-70% fuel damage in early April and to 35-55% fuel damage in late April ‘Melt-through’ at … Continue reading

Posted in doubtful assurances, incompetence, plant damage | Leave a comment

Groundwater contamination acknowledged by JAIF?

The Japan Atomic Industrial Forum on June 6 seems to agree that there is groundwater contamination at the plant that needs containment. See their June 6 update, an extract of which is below

Posted in plant damage, water leaks to sea | Leave a comment

Diagram of water flows in various basements…

TEPCO releases contaminated water tank construction schedule 06 June 2011 TEPCO, operator of the damaged Fukushima Daiichi nuclear power plant, has announced it plans to start a water treatment system for the flooded units 1-4 by 15 June. In addition, … Continue reading

Posted in basement water, plant damage | Leave a comment

Containment vessels also damaged-TEPCO

Containment vessels also damaged 26.05.2011 – Not only the pressure vessels, but the containment vessels of the Nos. 1 to 3 reactors at the Fukushima No. 1 nuclear power plant were probably damaged within 24 hours of the March 11 … Continue reading

Posted in fukushima, plant damage | Leave a comment

TEPCO still does not know how long cooling was turned off in #1

The operator of the Fukushima Daiichi nuclear power plant is still unable to determine how long an emergency cooling system at the Number 1 reactor remained off after the March 11 earthquake. Officials of Tokyo Electric Power Company spoke to … Continue reading

Posted in doubtful assurances, incompetence, plant damage | Leave a comment

Reactors stable now, #2 melted down 4 days after quake, fuel damage may still be limited

The operator of the troubled Fukushima Daiichi nuclear power complex said Tuesday that meltdowns are assumed to have occurred in the cores of the Nos. 2 and 3 reactors in addition to the meltdown already confirmed at the No. 1 … Continue reading

Posted in doubtful assurances, plant damage | Leave a comment

Reactors 2 and 3 also had meltdowns, TEPCO finally admits

Fukushima plant’s Nos. 2, 3 reactors also suffered meltdown: TEPCO TOKYO, May 24, Kyodo The operator of the troubled Fukushima Daiichi nuclear power complex said Tuesday that meltdowns are assumed to have occurred in the cores of the Nos. 2 … Continue reading

Posted in doubtful assurances, plant damage | Leave a comment